Navigation bar. See text links below.Home Page.Fenwal Thermoswitches & Detect-A-FireSealers & Packaging Equipment Home PageChillers, Cooling Towers, Screw Tips, Hopper Dryers, Ovens, etc.Price-Driscoll Mold Releases home pageMTS Temposonics Position TransducersWatlow Products Home PageCompany InfoWCPE Home Page

Temposonics Linear Transducers
R Series - Rod & Profile Style Position Sensors - Analog Output
The Temposonics R Series Linear Transducers are your solution when you need smart sensor capability for faster, higher precision, more reliable data processing and communication. By preprocessing sensor data in the sensor, your machine controller can reduce processing overhead and carry out other functions. Though the Temposonics R Series is at least four times faster than the other proven lines of Temposonics sensors, it’s also more precise: Resolution of 2 microns (0.00008 inch) at 10,000 measurements per second is standard; exceptional non-linearity of 0.02% uncorrected; and hysteresis of 0.00015 inches, which is the best in the industry.

Dual simultaneous analog outputs are offered as standard (i.e. one displacement & one velocity output using one magnet; or two identical displacement outputs using two magnets). R series sensors provide direct analog outputs, both voltage & current that allow 100% adjustment of zero and span setpoints. Since the outputs are direct, no signal conditioning electronics are needed when interfacing with controllers or meters.

Two application housings are available: rod-style (Model RH) and profile-style (Model RP). With RH sensors, the sensor cartridge can be quickly replaced in the field without removing the application housing. The changeover is done in one minute with no draining or de-pressurizing of the hydraulic cylinder.

ORDERING INFORMATION

SPECIFICATION SHEET
(pdf format)

INSTALLATION INSTRUCTIONS
(pdf format)

The Temposonics RP with Captive Sliding Magnet (top), Temposonics RP with Floating Magnet (middle) and Temposonics RH (bottom) with high-speed, high-resolution data transmission.

The Temposonics RH with field replaceable sensor cartridge.

Specifications

  • Measured Variable: Displacement
  • Resolution: 16 bit or 0.025mm, whichever is greater
  • Non-Linearity: <±0.02% of full stroke or ±0.05mm. whichever is greater.
  • Repeatability: <±0.001% of full scale or ±0.0025mm, whichever is greater.
  • Hysteresis: <0.004 mm.
  • Outputs:
    • Voltage: 0 to +10 Vdc or +10 to 0 Vdc
    • Current: 4 to 20 mA, 20 to 4 mA, 0 to 20 mA, 20 to 0 mA
  • Velocity:
    • Velocity Output Range: 0.1 to 10 m/s or 1.0 to 400.0 in/s
    • Minimum Velocity: 1.0 in/s ot 0.05 x stroke length in inches, whichever is greater
    • Maximum Velocity: 400.0 in/s or 100 x stroke length in inches, whichever is less (factory calibrated)
  • Measuring Range:
    • Profile Style (RP): 1 to 196 in. (25 to 4980 mm)
    • Rod Style (RH): 1 to 300 in. (25 to 7620 mm)
  • Operating Voltage: +24 Vdc, ±10% (For stroke lengths > 60 inches)
    • Power Consumption: 100 mA
    • Operating Temperature:
      • Head Electronics -40°F to 167°F
      • Sensing Element -40°F to 221°F
    • Update Time:
      • Analog: < 1ms typical (length dependent)
    • Warranty: 2 Years


    This page last modified on 5/14/02